<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-16 16-29-43
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.10 MHz 4/5, 38 dBuV CauseCom
Pilot RDS Phase Difference
8.1 kHz 4.3 kHz 89 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
20 kHz 40 kHz 1253 0,3192
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
3,1 dBr 4,36 dBr 5,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"CauseCom" FE46 9 (Varied) 0 0 1 1 --:--
RT
" "
AF EON
-
FM Scope Station: 93.10 MHz, signal: 4/5 (38 dBuV) Max at: 40 kHz MIN: 20 kHz % above 75 kHz: 0,3192 Acquired: 2025/03/16 16:28:40 Total samples: 1253 Equivalent time: 0:01:02 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 10 20 30
FM Scope MAX: 5,4 dBr MIN: 3,1 dBr AVE: 4,36 dBr % above 10,0 dBr: 0,0 Last value: 4,1 dBr (2025/03/16 16:28:39) Station: 93.10 MHz, signal: 4/5 (38 dBuV) 16:22 16:23 16:24 16:25 16:26 16:27 16:28 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality